Completion date: September 29, 2025 Location: Belvedere, VA Finis called us because his bedroom level heat pump was not cooling on a late summer hot day. We found a badly leaking indoor coil. We confirmed availability and price since the original installer never registered the system warranty. With approval we secured the coil and returned on Monday to replace the coil. We recovered any remaining refirgerant, tested for acid contamination, removed and replaced the filter drier and installed the new coil. Per standards, we floated dry nitrogen while brazing to prevent contamination, pressured tested and evacuated the system to confirm it was clean, dry and tight. Lastly we recharged the system with new refrigerant and returned the system to service. Kevin Bernardo-ZamoraJob completed for Finis M.